MilliplexCatalogID.HND3MAG-39K-01.HumanN

Code: HND3MAG-39K-01 D2-231

Application

Analytes: Angiotensinogen (AGT), Contactin-1, Fetuin A, Kallikrein-6, Osteopontin (OPN), Soluble Superoxide Dismutase 1 (SOD1), Soluble Superoxide Dismutase 2 (SO...


read more

Your Price
€1,216.70 EACH
€1,496.54 inc. VAT

Application

Analytes: Angiotensinogen (AGT), Contactin-1, Fetuin A, Kallikrein-6, Osteopontin (OPN), Soluble Superoxide Dismutase 1 (SOD1), Soluble Superoxide Dismutase 2 (SOD2) Recommended Sample type: CSF, serum, and plasma Recommended Sample dilution: 1:100 for CSF, 1:50 for serum and plasma for all analytes except Fetuin A, 1:4000 for serum and plasma for Fetuin A NOTE: Fetuin A cannot be assayed along with other analytes in serum/plasma samples. Fetuin A should be diluted 1:4000 in the kit Assay Buffer and analyzed as a singleplex for serum and plasma samples Assay Run Time: One day or Overnight Research Category: Neuroscience

Disclaimer

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Features and Benefits

Design your multiplex kit by choosing available analytes within this panel.

General description

Neurological disorders are diseases of the brain, spinal cord, and nerves. There are more than 600 diseases of the nervous system, such as Multiple sclerosis (MS), Alzheimer′s disease (AD), amyotrophic lateral sclerosis (ALS), Parkinson′s disease (PD), and stroke as well as frontotemporal dementia and many others. Identification of biomarkers for these neurological disorders allows scientists to identify early signs of neurological damage, track disease progression, and monitor efficacy of therapeutic treatment. The MILLIPLEX® 7-plex Human Neurological Disorders Bead Panel 3 is designed for the simultaneous measurement of multiple biomarkers in human cerebrospinal fluid (CSF), plasma, and serum using the Luminex® xMAP® instrument platform. The kit contains enough material to analyze 38 samples in duplicate, including the standard curve and two quality controls. NOTE: For serum and plasma samples Fetuin A requires a higher (1:4000) dilution and therefore must be assayed alone as a singleplex. For serum or plasma samples all analytes, except Fetuin A, require a 1:50 dilution and may be assayed together as a multiplex. The MILLIPLEX® Human Neurological Disorders Bead Panel 3 (Cat. No. HND3MAG-39K) is to be used for the simultaneous quantification of the following 7 analytes in any combination in CSF, serum or plasma samples: Angiotensinogen (AGT), Contactin-1, Fetuin A, Kallikrein-6, Osteopontin (OPN), Soluble Superoxide Dismutase 1 (SOD1), Soluble Superoxide Dismutase 2 (SOD2). NOTE: For serum and plasma samples Fetuin A requires a higher (1:4000) dilution and therefore must be assayed alone as a singleplex. For serum or plasma samples all analytes, except Fetuin A, require a 1:50 dilution and may be assayed together as a multiplex. Panel Type: Neuroscience

Legal Information

xMAP is a registered trademark of Luminex Corp

Luminex is a registered trademark of Luminex Corp

MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany

Other Notes

Sensitivity: Refer to kit protocol for sensitivities of individual biomarkers.

Packaging

Everything you need in a single kit.

Specificity

Cross ReactivtyThere was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes in this panel.

Storage and Stability

Recommended storage for kit components is 2 - 8°C.

assay rangestandard curve range: 1.37-1,000 ng/mL(AGT), standard curve range: 0.04-30 ng/mL(SOD1), standard curve range: 0.03-25 ng/mL(SOD2), accuracy: 71-107%(Serum), standard curve range: 0.04-30 ng/mL(Kallikrein-6), standard curve range: 0.14-100 ng/mL(Osteopontin (OPN)), standard curve range: 0.08-60 ng/mL(Contactin-1), standard curve range: 4.12-3,000 ng/mL(Fetuin A), accuracy: 69-92%(Cerebrospinal fluid (CSF))
detection methodfluorometric (Luminex xMAP)
manufacturer/tradenameMilliplex®
Quality Level200
shipped inwet ice
species reactivityhuman
technique(s)multiplexing: suitable
This product has met the following criteria to qualify for the following awards:



PROCEED TO CHECKOUT

HAVE AN ACCOUNT? LOGIN


GUEST CHECKOUT

Proceed as a guest. You will have the option to register to access exclusive pricing and stock availability features after checkout.