Ethidium Bromide Adsorber

Code: 331569-1EA D2-231

Biochem/physiol Actions

Cell permeable: no

Reversible: no

Primary TargetRemoval of ethidium bromide (EtBr) from aqueous staining solutions and running buffers

...


 Read more

Your Price
€157.35 EACH
€193.54 inc. VAT

Biochem/physiol Actions

Cell permeable: no

Reversible: no

Primary TargetRemoval of ethidium bromide (EtBr) from aqueous staining solutions and running buffers

Product does not compete with ATP.

General description

Developed specifically for the safe and simple removal of ethidium bromide (EtBr) from aqueous staining solutions and running buffers used in nucleic acid separation gels. Typical concentrations in these solutions are 0.5-10 mg/l. EtBr is bound and concentrated by the adsorber column, allowing removal of the filtrate. Each column normally binds at least 300 mg of ethidium bromide from TAE or TBE buffers. Residual capacity is easily visualized because the EtBr appears as a dark red to black band on the column. As long as this band has not reached the bottom of the column bed, the concentration of dye is still below the column capacity.

Developed specifically for the safe and simple removal of ethidium bromide (EtBr) from aqueous staining solutions and running buffers used in nucleic acid separation gels. Typical concentrations in these solutions are 0.5 - 10 mg/L. EtBr is bound and concentrated by the adsorber column, allowing removal of the filtrate. Each column normally binds at least 300 mg of ethidium bromide from TAE or TBE buffers. Residual capacity is easily visualized because the EtBr appears as a dark red to black band on the column. As long as this band has not reached the bottom of the column bed, the concentration of dye is still below the column capacity.

Legal Information

CALBIOCHEM is a registered trademark of Merck KGaA, Darmstadt, Germany

Other Notes

MacGregor, J.T., and Johnson, I.J. 1977. Mutat. Res.48, 103.Waring, M. 1975. In: Antibiotics, Corcoran, J.W., and Hahn, F.E., Editors, Vol. 3, 141, Cold Spring Harbor, NY.

Packaging

1 ea in Plastic ampoule

Reconstitution

When the adsorber column is not in use, both ends should be closed off. The column should not be allowed to dry out, as air bubbles may form in the column, hindering flow rate.

Warning

Toxicity: Irritant (B)

colorgray-brown
formsuspension
InChI keyNWUYHJFMYQTDRP-UHFFFAOYSA-N
InChI1S/C10H12.C10H10.C8H8/c2*1-3-9-7-5-6-8-10(9)4-2;1-2-8-6-4-3-5-7-8/h3,5-8H,1,4H2,2H3;3-8H,1-2H2;2-7H,1H2
manufacturer/tradenameCalbiochem®
Quality Level200
shipped inambient
storage conditionOK to freeze
storage temp.15-25°C
Cas Number69011-20-7