VOLATILE ORGANIC COMPOUNDS - WS

Code: PE1358-1KT D2-231

Application

Complete Volatiles Kit - WS proficiency testing material is suitable for testing volatile compounds in water supply/drinking water samples.Have any questions? Exp...


read more

Your Price
€277.15 1KIT
€340.89 inc. VAT

Application

Complete Volatiles Kit - WS proficiency testing material is suitable for testing volatile compounds in water supply/drinking water samples.Have any questions? Explore our FAQs.For more information on this product, please contact our PT Service Team.

Features and Benefits

We have a vast portfolio of environmental PT schemes with "fit-for-purpose" samples to help you meet the needs of the laboratory.Our proficiency testing (PT) program is a benchmark to: provide staff with an insight into their laboratory′s performance, to verify the accuracy and reliability of their testing process provide a comparison of performance with that of other laboratories, nationally and internationally test and educate staff, provide a better understanding of the impact of incorrect results and identify areas where there may be problems provide an independent evaluation of laboratory performance demonstrate to clients, colleagues and accreditation bodies that there is a commitment to quality

General description

Complete Volatiles Kit - WP proficiency testing material is produced in accordance with ISO/IEC 17043:2010. Also referred to as Potable Water or Water Supply sample, this sample is manufactured according to TNI requirements. However, please note, this sample may include non-TNI analytes as well. The lower criteria from the TNI tables mimic the levels common to drinking water samples.Supelco® is a global proficiency testing (PT) provider that manufactures best-in-class environmental and pharmaceutical PT products. Most water PT samples are available as concentrates or ready-to-use volumes giving the end-user flexibility in selecting samples that will fit their exact needs. Our WS program is designed to meet the quality assurance requirements in compliance with the Safe Drinking Water Act (SDWA), thereby ensuring the analytical competence of your laboratory or drinking water facility.These samples are typically provided in duplicate for use in case of lab mishap, for QC purposes or to analyze multiple methods.Type of PT Scheme: Water analysis - Water Supply (WS)Matrix: Water Supply/Drinking waterAnalyte/s: Randomly contains a minimum 80% of the analytes listed. Values of analytes vary lot to lot.All information regarding the use of Complete Volatiles Kit - WS can be found in the reporting packet which will be available to download at PT Portal.

Legal Information

Supelco is a registered trademark of Merck KGaA, Darmstadt, Germany

Other Notes

Are you new to Supelco® Proficiency TestingͰ Be sure to register your account details in the PT Portal before placing your order.This will provide access to data entry, reporting packets and final reports. Registrations will be approved shortly after your order is placed. For further questions, write to us at [email protected] placing your order online, please indicate your study preference under the ′your reference′ column. Available studies can be viewed at the bottom of the page.Click here to learn more about Quick-Turn Studies (on-demand proficiency tests that are offered depending on lot availability). The Quick-Turn results are released within 48-72 hours whereas scheduled study reports are released within 21 days.Proficiency testing samples are presented as single blind. No values for the samples are released until the testing period concludes.Proficiency Testing Schedule (2022-2023)Drinking WaterWS22-2 March 23 - May 6, 2022WS22-4 September 21 - November 4, 2022WS23-2 March 22 – May 5, 2023WS23-4 September 20 – November 3, 2023Quick-Turn Study (on demand proficiency testthat is offered depending on lot availability)

Preparation Note

Description The PT sample is provided as a 1.5 mL concentrate. The solvent is methanol. The PT sample is not preserved.Sample PreparationPlease read all instructions prior to preparation: Fill a 100 mL Class A Volumetric Flask to volume with organic-free reagent water. Using a gas-tight micro syringe, withdraw 20 µL of solution from PE1358 and inject into the expanded area of the flask, well below the surface of the water. Stopper the flask and mix by gentle inversion 3 times. Excessive mixing will result in loss of volatiles and should be avoided. This represents the sample for analysis.

Storage and Stability

Please refer to sample label for expiration date, specific storage temperature, and specific storage conditions.

application(s)environmental
concentrationin methanol
formatmulti-component solution
packagingampule of 2 × 1.2 mL
Quality Level100
This product has met the following criteria to qualify for the following awards:



PROCEED TO CHECKOUT

HAVE AN ACCOUNT? LOGIN


GUEST CHECKOUT

Proceed as a guest. You will have the option to register to access exclusive pricing and stock availability features after checkout.